![Maxim Integrated MAX32600 Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/maxim-integrated/max32600/max32600_user-manual_1744482067.webp)
MAX32600 User’s Guide
System Configuration and Management
4.1 Power Ecosystem and Operating Modes
Field
Bits
Default
Access
Description
v3_3_reset
3
0
W1C
3.3V Reset Monitor Int Flag
Write 1 to clear.
Set to 1 by hardware when the associated SVM event monitor detects the monitored condition.
PWRMAN_INTFL.vdda_warning
Field
Bits
Default
Access
Description
vdda_warning
4
0
W1C
VddA Warning Monitor Int Flag
Write 1 to clear.
Set to 1 by hardware when the associated SVM event monitor detects the monitored condition.
4.1.12.1.3
PWRMAN_INTEN
PWRMAN_INTEN.v1_8_warning
Field
Bits
Default
Access
Description
v1_8_warning
0
0
R/W
1.8V Warning Monitor Int Enable
0:Int disabled; 1:Interrupt enabled for the associated SVM monitor event.
PWRMAN_INTEN.v3_3_warning
Field
Bits
Default
Access
Description
v3_3_warning
1
0
R/W
3.3V Warning Monitor Int Enable
0:Int disabled; 1:Interrupt enabled for the associated SVM monitor event.