7.4 USB Device Interface
Write 1 to clear.
USB_OUT_INT.outdav1
Field
Bits
Default
Access
Description
outdav1
1
0
W1C
Endpoint 1 Data Available Interrupt Flag
This interrupt flag is set by the USB controller when it has successfully received an OUT packet from the host and has loaded it into the designated endpoint buffer.
This indicates that the packet data is available to be read by software.
Write 1 to clear.
USB_OUT_INT.outdav2
Field
Bits
Default
Access
Description
outdav2
2
0
W1C
Endpoint 2 Data Available Interrupt Flag
This interrupt flag is set by the USB controller when it has successfully received an OUT packet from the host and has loaded it into the designated endpoint buffer.
This indicates that the packet data is available to be read by software.
Write 1 to clear.
USB_OUT_INT.outdav3
Field
Bits
Default
Access
Description
outdav3
3
0
W1C
Endpoint 3 Data Available Interrupt Flag
This interrupt flag is set by the USB controller when it has successfully received an OUT packet from the host and has loaded it into the designated endpoint buffer.
This indicates that the packet data is available to be read by software.
Write 1 to clear.