MAX32600 User’s Guide
Communication Peripherals
7.4 USB Device Interface
USB_OUT_INT.outdav4
Field
Bits
Default
Access
Description
outdav4
4
0
W1C
Endpoint 4 Data Available Interrupt Flag
This interrupt flag is set by the USB controller when it has successfully received an OUT packet from the host and has loaded it into the designated endpoint buffer.
This indicates that the packet data is available to be read by software.
Write 1 to clear.
USB_OUT_INT.outdav5
Field
Bits
Default
Access
Description
outdav5
5
0
W1C
Endpoint 5 Data Available Interrupt Flag
This interrupt flag is set by the USB controller when it has successfully received an OUT packet from the host and has loaded it into the designated endpoint buffer.
This indicates that the packet data is available to be read by software.
Write 1 to clear.
USB_OUT_INT.outdav6
Field
Bits
Default
Access
Description
outdav6
6
0
W1C
Endpoint 6 Data Available Interrupt Flag
This interrupt flag is set by the USB controller when it has successfully received an OUT packet from the host and has loaded it into the designated endpoint buffer.
This indicates that the packet data is available to be read by software.
Write 1 to clear.
USB_OUT_INT.outdav7
Rev.1.3 April 2015