MAX32600 User’s Guide
Communication Peripherals
7.1 I²C
Write to 1 to begin a master transaction.
I2CMn_TRANS.tx_in_progress
Field
Bits
Default
Access
Description
tx_in_progress
1
0
R/O
Transaction In Progress
Set to 1 by hardware when a new transaction is started; cleared when transaction ends.
I2CMn_TRANS.tx_done
Field
Bits
Default
Access
Description
tx_done
2
0
R/O
Transaction Done
Set to 1 by hardware when a transaction completes; cleared to 0 on transaction Start.
I2CMn_TRANS.tx_nacked
Field
Bits
Default
Access
Description
tx_nacked
3
0
R/O
Transaction Nacked
Set to 1 when a transaction completes due to an unexpected NACK; cleared to 0 on Start.
I2CMn_TRANS.tx_lost_arbitr
Field
Bits
Default
Access
Description
tx_lost_arbitr
4
0
R/O
Transaction Lost Arbitration
Set to 1 when a transaction halts due to an arbitration failure; cleared to 0 on Start.
Rev.1.3 April 2015
Maxim Integrated
Page 233
Содержание MAX32600