MAX32600 User’s Guide
Communication Peripherals
7.4 USB Device Interface
Field
Bits
Default
Access
Description
outdav7
7
0
W1C
Endpoint 7 Data Available Interrupt Flag
This interrupt flag is set by the USB controller when it has successfully received an OUT packet from the host and has loaded it into the designated endpoint buffer.
This indicates that the packet data is available to be read by software.
Write 1 to clear.
7.4.4.1.12
USB_NAK_INT
USB_NAK_INT.nak0
Field
Bits
Default
Access
Description
nak0
0
0
W1C
Endpoint 0 NAK Interrupt Flag
This interrupt flag is set by the USB controller after it sends a NAK handshake to the host in response to an IN request. This indicates that the endpoint buffer has no
data available to be transmitted to the USB host.
Write 1 to clear.
USB_NAK_INT.nak1
Field
Bits
Default
Access
Description
nak1
1
0
W1C
Endpoint 1 NAK Interrupt Flag
This interrupt flag is set by the USB controller after it sends a NAK handshake to the host in response to an IN request. This indicates that the endpoint buffer has no
data available to be transmitted to the USB host.
Write 1 to clear.
USB_NAK_INT.nak2
Field
Bits
Default
Access
Description
nak2
2
0
W1C
Endpoint 2 NAK Interrupt Flag
Rev.1.3 April 2015