MAX32600 User’s Guide
Analog Front End
8.4 DAC
Note
If Interpolation Mode is enabled (as discussed below), this parameter applies to the output rate of values after interpolation. The Rate Count
parameter is set by writing to the
field; the actual value of the Rate Count parameter is equal to (
+ 2). For example,
to set the Rate Count to 20 clock cycles, the
field should be set to 18.
• The optional
Interpolation Mode parameter
can be set to generate linearly interpolated data points between each two sample code values loaded into the
FIFO. For example, if the FIFO contains two data points, A1 and A2, and A2
>
A1, the output sample sequence generated will vary depending on interpolation
mode as follows:
–
No interpolation
:
*
A
1
*
A
2
–
Interpolation 2-to-1
:
*
A
1
*
A
1
+ (
A
2
−
A
1
)
×
1
2
*
A
2
–
Interpolation 4-to-1
:
*
A
1
*
A
1
+ (
A
2
−
A
1
)
×
1
4
*
A
1
+ (
A
2
−
A
1
)
×
1
2
*
A
1
+ (
A
2
−
A
1
)
×
3
4
*
A
2
–
Interpolation 8-to-1
:
*
A
1
*
A
1
+ (
A
2
−
A
1
)
×
1
8
*
A
1
+ (
A
2
−
A
1
)
×
2
8
*
A
1
+ (
A
2
−
A
1
)
×
3
8
*
A
1
+ (
A
2
−
A
1
)
×
4
8
*
A
1
+ (
A
2
−
A
1
)
×
5
8
*
A
1
+ (
A
2
−
A
1
)
×
6
8
*
A
1
+ (
A
2
−
A
1
)
×
7
8
*
A
2
Rev.1.3 April 2015
Maxim Integrated
Page 457
Содержание MAX32600
Страница 1: ...MAX32600 User s Guide April 2015...