MAX32600 User’s Guide
Flash Controller and Instruction Cache
14.1 Registers (FLC)
• 0: Original flash access design; xaddr and yaddr are activated the same clock edge as SE
• 1: Inserts an additional clock cycle before SE is driven active (safety margin, slows down read accesses) (default)
FLC_PERFORM.delay_se_en
Field
Bits
Default
Access
Description
delay_se_en
0
1
R/W
Delay SE Enable
• 0: Original flash access mode, 8-9 cycles for read access (default)
• 1: Fast read mode - the flash controller will perform back-to-back flash reads for an access time of 2-3 cycles per read cycle (after the 2nd)
14.1.1.7
FLC_STATUS
FLC_STATUS.debug_lock_window
Field
Bits
Default
Access
Description
debug_lock_window
0
s
R/O
Debug Locked - Hardware Window
• 0: No lockout from this source
• 1: The debug lockout is being asserted because the debug hardware window lockout feature is active, and the window of 1024 cycles following reset has not
yet elapsed.
FLC_STATUS.debug_lock_static
Field
Bits
Default
Access
Description
debug_lock_static
1
s
R/O
Debug Locked - Firmware Lockout
Rev.1.3 April 2015
Maxim Integrated
Page 657
Содержание MAX32600