MAX32600 User’s Guide
Communication Peripherals
7.1 I²C
Address
Register
32b
Word Len
Description
0x40041000
1
Full Speed SCL Clock Settings
0x40041004
1
High Speed SCL Clock Settings
0x40041008
1
Slave Device ID Settings
0x4004100C
1
Timeout and Auto-Stop Settings
0x40041010
1
I2C Slave Interface Control Register
0x40041020
1
Interrupt Flags
0x40041024
1
Interrupt Enable/Disable Controls
0x40041028
1
Bit-Bang Control Register
0x4004102C
1
RX FIFO Peek (Read from end without pull operation)
0x40104000
512
I2C Slave Receive Data FIFO
0x40104800
512
I2C Slave Transmit Data FIFO
7.1.9.1.1
I2CS0_FS_CLK_DIV
I2CS0_FS_CLK_DIV.fs_filter_clk_div
Field
Bits
Default
Access
Description
fs_filter_clk_div
7:0
00000001b
R/W
Full Speed Filter Clock Divisor
Filter frequency = I2C module clock/bits[7:0]; 1=Off
I2CS0_FS_CLK_DIV.fs_scl_lo_cnt
Field
Bits
Default
Access
Description
fs_scl_lo_cnt
19:8
12’b0
R/W
Full Speed SCL Low Count
Number of clocks to hold SCL low for clock output
Rev.1.3 April 2015
Maxim Integrated