MAX32600 User’s Guide
Analog Front End
8.3 ADC
Field
Bits
Default
Access
Description
cpu_pga_trk_dly
4
1
R/W
Reserved Field - Do Not Modify
This field should not be modified by the user. For proper operation, this field must be left at its default value.
ADC_PGA_CTRL.cpu_pga_trk
Field
Bits
Default
Access
Description
cpu_pga_trk
5
0
R/W
Reserved Field - Do Not Modify
This field should not be modified by the user. For proper operation, this field must be left at its default value.
ADC_PGA_CTRL.cpu_pga_bypass
Field
Bits
Default
Access
Description
cpu_pga_bypass
6
0
R/W
PGA Bypass Control
0: Normal mode, PGA path active 1: PGA bypass, input mux drives ADC
ADC_PGA_CTRL.pga_wake_cnt
Field
Bits
Default
Access
Description
pga_wake_cnt
12:8
5’15h
R/W
PGA Wakeup Counter
Length of time (defined in number of ADC clocks) that is allowed for the PGA to turn on. Minimum is 15h. Longer values would allow longer PGA acquisition time on
first sample or during reduced sample rate modes.