MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.1 System Clock
10.1.5.1.20
CLKMAN_CLK_CTRL_13_RTC_INT_SYNC
CLKMAN_CLK_CTRL_13_RTC_INT_SYNC.rtc_clk_scale
Field
Bits
Default
Access
Description
rtc_clk_scale
3:0
0000b
R/W
Control Settings for CLK13 - RTC Interrupt Sync
Clock
• 0000b: CLK is Disabled
• 0001b: CLK = (System Clock Source / 1)
• 0010b: CLK = (System Clock Source / 2)
• 0011b: CLK = (System Clock Source / 4)
• 0100b: CLK = (System Clock Source / 8)
• 0101b: CLK = (System Clock Source / 16)
• 0110b: CLK = (System Clock Source / 32)
• 0111b: CLK = (System Clock Source / 64)
• 1000b: CLK = (System Clock Source / 128)
• 1001b: CLK = (System Clock Source / 256)
• other: CLK = (System Clock Source / 1)
This clock is disabled by default following reset.
10.1.5.1.21
CLKMAN_CLK_CTRL_14_DAC0
CLKMAN_CLK_CTRL_14_DAC0.dac0_clk_scale
Field
Bits
Default
Access
Description
dac0_clk_scale
3:0
0000b
R/W
Control Settings for CLK14 - 12-bit DAC 0
Clock
Rev.1.3 April 2015
Maxim Integrated
Page 534
Содержание MAX32600