13.4 Registers (LCD)
13.4.1.5
LCD_LCDATA
LCD_LCDATA.none
Field
Bits
Default
Access
Description
n/a
7:0
00h
R/W
LCD Display Memory Read/Write
Reading from or writing to accesses the current
location in LCD data memory selected by LCADDR.
13.4.1.6
LCD_LPWRCTRL
LCD_LPWRCTRL.powerup
Field
Bits
Default
Access
Description
powerup
0
0
R/W
lcd_pu - LCD Powerup
0: Powered down; 1: Powered up
LCD_LPWRCTRL.freerun
Field
Bits
Default
Access
Description
freerun
1
0
R/W
lcd_freerun
LCD_LPWRCTRL.highbat_startup
Field
Bits
Default
Access
Description
highbat_startup
2
0
R/W
lcd_highbat_startup