![Maxim Integrated MAX32600 Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/maxim-integrated/max32600/max32600_user-manual_1744482066.webp)
MAX32600 User’s Guide
System Configuration and Management
4.1 Power Ecosystem and Operating Modes
1: Enables dynamic clock gating for pwrman functions.
4.1.12.1.2
PWRMAN_INTFL
PWRMAN_INTFL.v1_8_warning
Field
Bits
Default
Access
Description
v1_8_warning
0
0
W1C
1.8V Warning Monitor Int Flag
Write 1 to clear.
Set to 1 by hardware when the associated SVM event monitor detects the monitored condition.
PWRMAN_INTFL.v3_3_warning
Field
Bits
Default
Access
Description
v3_3_warning
1
0
W1C
3.3V Warning Monitor Int Flag
Write 1 to clear.
Set to 1 by hardware when the associated SVM event monitor detects the monitored condition.
PWRMAN_INTFL.rtc_warning
Field
Bits
Default
Access
Description
rtc_warning
2
0
W1C
RTC Warning Monitor Int Flag
Write 1 to clear.
Set to 1 by hardware when the associated SVM event monitor detects the monitored condition.
PWRMAN_INTFL.v3_3_reset
Rev.1.3 April 2015
Maxim Integrated
Page 48