MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.1 System Clock
Dynamic clock gating control.
• 00b: Clock Off
• 01b: Dynamic Clock Gating Enabled
• 1xb: Clock On
CLKMAN_CLK_GATE_CTRL0.timer1_clk_gater
Field
Bits
Default
Access
Description
timer1_clk_gater
21:20
01b
R/W
Clock Gating Control for Timer Module 1
Dynamic clock gating control.
• 00b: Clock Off
• 01b: Dynamic Clock Gating Enabled
• 1xb: Clock On
CLKMAN_CLK_GATE_CTRL0.timer2_clk_gater
Field
Bits
Default
Access
Description
timer2_clk_gater
23:22
01b
R/W
Clock Gating Control for Timer Module 2
Dynamic clock gating control.
• 00b: Clock Off
• 01b: Dynamic Clock Gating Enabled
• 1xb: Clock On