MAX32600 User’s Guide
Flash Controller and Instruction Cache
14.1 Registers (FLC)
FLC_CTRL.flsh_unlock
Field
Bits
Default
Access
Description
flsh_unlock
31:28
0000b
R/W
Flash Write/Erase Enable
0010b/2d: Flash write and erase operations are enabled.
14.1.1.4
FLC_INTR
FLC_INTR.started_if
Field
Bits
Default
Access
Description
started_if
0
0
R/W
Flash Operation Started
Write to zero to clear bit to 0.
Set to 1 by hardware when a flash operation (write or erase) starts.
FLC_INTR.failed_if
Field
Bits
Default
Access
Description
failed_if
1
0
R/W
Flash Operation Failed
Write to zero to clear bit to 0.
Set to 1 by hardware when an error occurs during a flash operation
FLC_INTR.started_ie