Analog Front End
8.5 LED
8.5.2.4
Independent Loop H-bridge LED Configuration
Figure 8.14: Independent Loop H-bridge LED Configuration
When the digital controls switch the loop open then closed again, undesirable loop behavior may occur and must be controlled. Further, only one diode can be
activated at any one time. These circumstances may necessitate the use of more than one op amp. Here, the
MAX32600
can provide two independent control loop
paths as a possible solution to these problems.
The independent loop H-bridge LED configuration allows two diodes to operate simultaneously on independent control loop paths. This avoids transient interference
during operation and enables the loops to be on continuously. Each control loop can be configured with any of the diode drivers. However, only one control loop may
be directly managed by pulse trains.
Rev.1.3 April 2015