MAX32600 User’s Guide
Communication Peripherals
7.1 I²C
Field
Bits
Default
Access
Description
restart_id0
10
0
W1C
Restart Detected (ID0) Interrupt Status
Write 1 to clear.
Set to 1 by hardware when the I2C slave detects a restart event (ID0).
I2CS0_INTFL.restart_id1
Field
Bits
Default
Access
Description
restart_id1
11
0
W1C
Restart Detected (ID1) Interrupt Status
Write 1 to clear.
Set to 1 by hardware when the I2C slave detects a restart event (ID1).
I2CS0_INTFL.stop_id0
Field
Bits
Default
Access
Description
stop_id0
12
0
W1C
Stop Detected (ID0) Interrupt Status
Write 1 to clear.
Set to 1 by hardware when the I2C slave detects a Stop event (ID0).
I2CS0_INTFL.stop_id1
Field
Bits
Default
Access
Description
stop_id1
13
0
W1C
Stop Detected (ID1) Interrupt Status
Write 1 to clear.