background image

 

 

 

PIP 100 

 

                                      Operating Instructions 

 

230V 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
Dear Customer 
 
This  handbook  is  intended  to  help  you  with  the 
operation of your PIP 100. It is important to read the 
instructions  carefully  and  to  follow  the  directions 
closely in order to avoid disruptions due to operating 
errors.  By  following  instructions  properly,  your 
equipment  will  always  be  ready  for  use  and  serve 
you over a long lifespan.  

 
Operation  of  the  device  should  only  be  done  by 
trained professionals and be operated according 
to 

the 

intended 

purpose 

of 

use. 

The 

manufacturer is in no way liable for any damage 
caused  by  improper  use  and  operation.  Before 
use  please  be  sure  to  read  the  manual  sections 
“General 

Safety 

Requirements”, 

“Personal 

Protection” and the Safety Precautions. 
 
 

Please retain these instructions for reference. 
 
 
 
 
 

Note on Symbol 
 
The 

equipment 

manufactured 

by 

“Lampert 

Werktechnik  GmbH“fulfil  the  standard  requirements 
of  CE  certification  and  are  manufactured  according 
to VDE guidelines.  
 
Use  original  parts  only  for  maintenance  and 
updating.  Our  customer  service  department  with 
expertly  trained  staff,  suitable  resources  and 
equipment would be pleased to help you further.  
 

The  device  should  only  be  opened  or  modified 
by  authorized  customer  service  technicians, 
otherwise  all  warrantees  and  liability  claims  will 
be void. 
 
 
 
LAMPERT WERKTECHNIK GMBH 

 

May 2007 

Содержание PIP 100

Страница 1: ...mage caused by improper use and operation Before use please be sure to read the manual sections General Safety Requirements Personal Protection and the Safety Precautions Please retain these instructions for reference Note on Symbol The equipment manufactured by Lampert Werktechnik GmbH fulfil the standard requirements of CE certification and are manufactured according to VDE guidelines Use origin...

Страница 2: ...Basic Information and Tips 11 4 6 Grinding the Electrodes 11 SECTION 5 MAINTENANCE 11 SECTION 6 TECHNICAL DATA 12 6 1 Technical Data 12 6 2 Identification Plate 12 SECTION 7 TROUBLESHOOTING 13 SECTION 8 EC DECLARATION OF CONFORMITY 14 SECTION 1 GENERAL APPLICATION OF THE WELDING DEVICE PIP 100 intended use the placement of spot welding on precious metal and precious metal alloys on steel and steel...

Страница 3: ... ex works This means that it also may be operated using 220 volts due to its tolerance of 15 Devices set to a different voltage than 230 V will be marked with a special sticker If the PIP 100 is switched for a voltage other than 230V it will have a sticker with the corresponding voltage The device should only be opened by authorized customer service otherwise the manufacturer s warrantee is invali...

Страница 4: ...t cover the device Always place the device on a hard non combustible insulated material base Do not allow metal dust e g during abrasion work to directly enter the device 3 2 DESCRIPTION OF THE CONTROL ELEMENTS CONTROLLER Fig 1 INDICATION AREA 1 CONTROL AND MEMORY KEYS 2 ACTIVATOR FOR AUXILIARY LIGHTING 3 ACTIVATOR ELECTRODE SHARPENING ENGINE 4 ...

Страница 5: ...ET FOR AUXILIARY LIGHTING 6 CONNECTING SOCKET FOR GRINDING ENGINE 7 CONNECTING SOCKET FOR HANDPIECE 10 CONNECTING SOCKETS FOR CONTACT ELEMENTS 9 such as welding table welding clamp holding plier Safety patch cord In order to plug off an insert plug it is essential to first press this plug into the socket to detach the locking ...

Страница 6: ...R 12 for 6 0mm pressure tube min 3 bar 43psi max 10 bar 145psi oil free FUSEBOX 13 Welding current T10AH 5x20mm FUSEBOX 14 Auxiliary lighting T2 5AH 5x20mm FUSEBOX 15 Power Fuse T4AH 5x20mm MAIN SWITCH 16 APPLIANCE COUPLERS 17 Connection of the mains cable SHIELDING GAS CONNECTOR 18 for 6 0mm pressure tube max 4 bar 58psi PC CONNECTION 19 ...

Страница 7: ...nnection socket 5 marked Filter located on the front side of the device and secure it with the nut Attach the pressure controller to the protective gas container after carefully reading the instructions if possible use argon gas with a minimum of 99 9 e g Argon 4 6 or an inert gas mixture suitable for your application Connect pressure tube by using the quick connectors to the pressure controller a...

Страница 8: ... cancel memory procedure Save store current parameters Auxiliary lighting on off Grinding engine on off 4 2 DISPLAY Achievement in the per cent of 15 100 in 5 stages Welding time in ms of 3ms 52ms Devices interior temperature Hand piece temperature Charge welding tension 1 5 Welding Impulse shape 1 6 Gas pressure in bar Status and or error display Selected programme number ...

Страница 9: ... and key Using the or key the memory procedure can be discontinued The S Key needs to be pressed again for 2 seconds to close the memory procedure With release the S key the current parameters are stored into the selected program place SELECTION OF WELDING TENSION Different welding tensions can be selected in the menu charge Charge Welding Tension in V 1 38 2 39 5 3 40 5 4 41 5 5 43 The welding te...

Страница 10: ...ure sinks under 35 C the compressed air valve is closed and the hand piece cooling is deactivated Also by starting a welding procedure the compressed air valve is closed If the hand piece temperature reaches 53 the cooli ng is obligation switched on If the hand piece temperature falls under 53 the c ooling can be stopped by starting a new welding procedure GAS PRESSURE SETTING Adjust the pressure ...

Страница 11: ...an serve well as a welding addition Allow the needle to clamp in longer for deep lying welding spots If you work with adding material use only suitable welding wires If you have problems igniting it may be helpful to lightly press the needle sideways Using this technique you will be able to push welding spot in a certain direction 4 6 GRINDING THE ELECTRODES Figure 4 The electrodes must be ground ...

Страница 12: ...ended ARGON 99 9 ARGON 4 6 maximum gas pressure 4 bar 58psi Compressed air max 10 bar 145psi Cyclic duration X 80 Protection class system I Insulation category B Protection type IP21S Weight 16 kg 6 2 IDENTIFICATION PLATE Description of symbols Amperage Voltage Protection Method Hertz Alternating Current AC Tungsten Inert Gas Welding Direct Current 1 50 60Hz Power plug single phase Alternating Cur...

Страница 13: ...ormation Heavy gas pressure sufficient Reduce flow amount 8 Strong oxidation of welding spots wrong protective gas no protective gas Use inert protective gas ARGON 4 6 9 Tungsten contamination in basic material Electrode with too high pressure onto work piece Touch work piece with very slight pressure so that it manages to ignite 10 Tungsten Electrode sticks to work piece Electrode with too high p...

Страница 14: ...es that the product Precision Welding Device PIP 100 conforms to the conditions set forth in the above named guidelines including any changes made up to the time of declaration The following harmonised standards were used Welding current sources for arc hand welding in limited operation DIN VDE 0543 VDE 0543 Protective housing type IP Code DIN EN 60529 VDE 0470 1 Electro magnetic compatibility EMV...

Страница 15: ...15 ...

Отзывы: