SECTION 6 – TECHNICAL DATA
6-1. TECHNICAL DATA
•
Device suitable for welding in dry rooms.
•
Temperature range 5-40°C
•
Altitude indication: Not over 2000 m NN
•
Air humidity: Max one. 80 % to 31°C max. 50 % of 31 -40°C
•
Mains voltage ~230 V/50-60 cycles per second of +/-15%
•
Net security T 4 AH
•
Capacity 1200 VA
•
Normal voltage 38 - 43 V
•
Open circuit voltage 3 V
•
max. load time 1.7 sec
•
Inert gas: recommended ARGON 99.9% (ARGON 4,6)
•
maximum gas pressure 4 bar (58psi
)
•
Compressed air max. 10 bar (145psi)
•
Cyclic duration X: 80 %
•
Protection class system I
•
Insulation category B
•
Protection type IP21S
•
Weight 16 kg
6-2. IDENTIFICATION PLATE
Description of symbols:
Amperage
Voltage
Protection
Method
Hertz
Alternating
Current (AC)
Tungsten-Inert-
Gas-Welding
Direct Current
1 ~ 50-60Hz
Power plug
single phase /
Alternating
Current / 50-
60Hz
Read the
manual
Idling Voltage
Mains Voltage
Ground
Nominal
Voltage
Nominal
welding current
Single phase
transformer
Amperage input
Rated
Amperage input
Duty cycle