10
STATUS INDICATION AND ERROR MESSAGES
Run
Devices ready for use
Wait
Indication during the welding procedure
Store
Memory procedure activated
Save
Storage of the current parameter in the selected memory
S-Fail
Faulty shutter (eye protection filter incorrectly)
G-Fail
Gas fault: Gas pressure under 0,10 bar / 1,45 psi during the welding procedure
Solve error and weld again
H-Fail
Hand piece not connected
Control hand piece connection
T-Fail
Temperature error, hand piece temperature over 52°C
Compressed air cooling is switched on
HAND PIECE COOLING
The function "hand piece cooling" presupposes a compressor air bleed port.
If no compressor air bleed port is available the "hand piece cooling" is deactivated.
Starting from a hand piece temperature of 40°C the hand piece cooling is activated.
If compressed air is connected the compressed air valve is opened and the hand piece is cooled after 10 seconds of work
break.
If the hand piece temperature sinks under 35°C the compressed air valve is closed and the hand piece cooling is deactivated.
Also by starting a welding procedure the compressed air valve is closed.
If the hand piece temperature reaches 53° the cooli ng is obligation-switched on.
If the hand piece temperature falls under 53° the c ooling can be stopped by starting a new welding procedure.
GAS PRESSURE SETTING
Adjust the pressure reducing valve to a flow rate of 3-5l/min.
Note: The maximum pressure amounts to 4 bar / 58psi.
If the gas pressure is adjusted higher, the internal gas regulation can be damaged.
4-4. WELDING GUIDELINES
•
Use a clamp though the work piece can be connected to the ground connection
•
Make sure there is good contact between work piece and table
•
Use the electrode tip to touch the area you want to weld until the welding is complete.
“Without pressure or only with slight pressure!”
•
The welding process takes place automatically:
o
protective gas floats around welding spot
o
A signal tone indicates the arc
o
the arc sets off
o
protective gas supply stops
•
The welding procedure can be interrupted at any time by taking off the electrode from the work piece