Included in this Product Package:
Step 1: Select Location for TCX7
TCX7 mounting location should be conveniently and easily
accessible. If possible, mount TCX7 centered between two
consecutive wall studs to minimize chances of interference. Do
not mount TCX7 where it may interfere with electrical wiring, water
lines, or any other existing infrastructure. In order to conform to
ADA standards, do not mount TCX7 higher than 48” off of the
ground. TCX7, once mounted, occupies a space 8” wide & 5 ½” tall.
Step 2: Cut Hole for Mounting Single Gang Bracket
In desired TCX7 location, lightly sketch a 2 1/8” wide by 3 5/8” tall rectangle for
locating the single gang bracket. Confirm that the space behind this rectangle is
free of electrical wiring, water lines, wall studs, or any other obstructions.
Using a drywall saw, carefully cut out the rectangle, and discard the interior
portion. Using a vacuum, carefully clean away any drywall dust remaining from
the cutting process.
Step 3: Mount Single Gang Bracket
Ensuring that “UL” logo is in the top left corner of the single gang bracket, firmly
press the bracket into the rectangular cutout in the wall. Make sure that the bracket
seats fully into the wall, with all sides flush against the outer surface.
With the bracket inserted into the wall, gently tighten the two (2) silver screws built
into the bracket. These screws rotate and secure the mounting flanges against
the opposite side of the wall, ensuring the TCX7 will be secure. Tighten screws
until snug.
Do not overtighten
, as this can cause the bracket to warp. Once both
screws are tightened, check that bracket is secure and stable.
TCX7 Touchscreen
Controller
Device Plate
Single Gang
Bracket
6-32 Machine
Screws (2)