Commands for Status Monitoring and Statistics
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
704
To view the temperature of the fan trays installed in the BlackDiamond 10808 switch, use the following
command:
show fans {detail}
Example
Depending on the platform, the following command displays the temperature of various switch
components:
show temperature
The following is sample output from a modular switch:
Field Replaceable Units Temp (C) Status
------------------------------------------------
Slot-1 : 10G6X 36.37 Normal
Slot-2 : G60X 35.31 Normal
Slot-3 :
Slot-4 :
Slot-5 :
Slot-6 : G60X 34.68 Normal
Slot-7 : G60X 34.31 Normal
Slot-8 :
MSM-A : MSM-1XL 31.37 Normal
MSM-B : MSM-1XL 29.75 Normal
PSUCTRL-1 :
PSUCTRL-2 : 29.00 Normal
Temp Range: -10.00 (Min), 0.00-50.00 (Normal), 60.00 (Max)
The following is sample output from a Summit X450 series switch:
Field Replaceable Units Temp (C) Status
----------------------------------------------------
Switch : SummitX450-24x 32.00 Normal
XGM-2xn-1 :
Temp Range: -10.00 (Min), 0.00-60.50 (Normal), 62.90 (Max)
History
This command was first available in an ExtremeWare XOS 10.1.
Information about the power controller(s), a component status column, and the minimum, normal, and
maximum temperature ranges of the components was added to the
show temperature
output in
ExtremeWare XOS 11.0.
Information about the XGM-2xn card was added to the
show temperature
output in ExtremeWare XOS
11.2.
Platform Availability
This command is available on all platforms.