Commands for Status Monitoring and Statistics
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
598
configure sflow poll-interval
configure sflow poll-interval <seconds>
Description
Configures the sFlow counter polling interval.
Syntax Description
Default
The default polling interval is 20 seconds.
Usage Guidelines
Each sFlow statistics counter is polled at regular intervals, and this data is then sent to the sFlow
collector. This command is used to set the polling interval. To manage CPU load, polling for sFlow
enabled ports are distributed over the polling interval, so that all ports are not polled at the same
instant. For example, if the polling interval is 20 seconds and there are twenty counters, data is collected
successively every second.
Specifying a poll interval of 0 (zero) seconds disables polling.
Example
The following command sets the polling interval to 60 seconds:
configure sflow poll-interval 60
History
This command was first available in ExtremeWare XOS 11.0.
Platform Availability
This command is available on all platforms with an Advanced Edge, a Core, or an Advanced Core
license.
seconds
Specifies the number of seconds between polling each counter. The value can
range from 0 to 3600 seconds.