Commands for Managing the Switch
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
204
■
Down: The module is installed, but the administrator has taken the module offline.
■
Power ON: There is sufficient system power to power up the module.
■
Powered OFF: There is insufficient system power to keep the module up and running, or there is
a mismatch between the module configured for the slot and the actual module installed in the
slot.
■
Booting: The module has completed downloading the software image and is now booting.
■
Initializing: The module is initializing.
●
Watts and voltage amounts of the modules.
●
Power Surplus or Power Shortfall.
■
If the amount of available power meets or exceeds the required port, the excess is displayed as
the Power Surplus.
■
If the available power is insufficient to meet the required power, the deficit is displayed as Power
Shortfall.
●
Redundant power information. If the amount of redundant power meets or exceeds the required
power, the system has (N+1) power.
■
Yes—The system has redundant (N+1) power.
■
No—The system does not have redundant (N+1) power.
The information contained in this display is for planning purposes since the system operates without
redundant power as long as a power surplus is shown. However, if power is lost to a single PSU
when the system is not redundant, I/O modules are powered down. Please refer to the section
“Understanding Power Supply Management”
in
Chapter 3, “Managing the Switch,”
of the
ExtremeWare XOS Concepts Guide
.
Depending on the software version running on your switch, the modules installed in your switch, and
the type of switch you have, additional or different power information may be displayed.
Example
The following command displays the distribution of power and the available power on the switch:
show power budget
The following is sample output of this command from a BlackDiamond 10808 switch:
PS State Watts 48V 12V
---------------------------------------------------------------------------
1 Powered On 656.00 608.00 48.00
2 Powered On 656.00 608.00 48.00
3 Empty
4 Empty
5 Powered On 656.00 608.00 48.00
6 Empty
---------------------------------------------------------------------------
Power Available: 1968.00 1824.00 144.00
Redundant (N+1) Power Available: 1344.00 1248.00 96.00
Slots Type State Watts 48V 12V
---------------------------------------------------------------------------
Slot-1 Empty
Slot-2 Empty
Slot-3 Empty