reset inline-power ports
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
533
reset inline-power ports
reset inline-power ports <port_list>
Description
Power cycles the specified ports.
Syntax Description
Default
N/A.
Usage Guidelines
This command power cycles the specified ports. Ports are immediately disabled and then re-enabled,
allowing remote PDs to be power-cycled.
This command affects only inline power; it does not affect network connectivity for the port(s).
Example
The following command resets power for port 4 on slot 3 on a modular switch:
reset inline-power ports 3:4
History
This command was first available in ExtremeWare XOS 11.1.
Platform Availability
This command is available on the G48P and G48Pe modules installed in the BlackDiamond 8800 series
switch and the Summit X450e-24p switch.
portlist
Specifies one or more ports or slots and ports for which power is to be reset.