Commands for Status Monitoring and Statistics
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
654
●
If you enable sFlow globally on the switch and on original I/O module ports and you try to enable
mirroring on original, a-series, or e-series I/O module ports, the switch displays a message similar to
the following:
Error: Mirroring is not compatible with SFlow. Mirroring not enabled!
Configuration failed on backup MSM, command execution aborted!
If you see the above message, you must disable sFlow on all of the original I/O module ports.
●
If you enable sFlow globally on the switch and on a-series or e-series I/O module ports and you try
to enable mirroring on original I/O module ports, the switch does not display an error. You can
successfully enable mirroring on original I/O module ports, provided you do not enable sFlow on
original I/O module ports.
●
If you enable sFlow on original I/O module ports, sFlow uses QP2 to sample traffic. When enabling
sFlow on those ports, the switch displays a message similar to the following:
SFLOW will use Qos Profile QP2.
For more information about the BlackDiamond 8800 a-series, e-series modules, and original modules see
Chapter 1, “ExtremeWare XOS Overview”
in the
ExtremeWare XOS Concepts Guide
and the
Extreme
Networks Consolidated ExtremeWare XOS Hardware Guide
. For more information about mirroring, see
Chapter 5, “Configuring Slots and Ports on a Switch”
in the
ExtremeWare XOS Concepts Guide
. For more
information about QOS, see
Chapter 16, “Quality of Service”
in the
ExtremeWare XOS Concepts Guide
.
Example
The following command enables sFlow sampling on the port 3:1:
enable sflow ports 3:1
History
This command was first available in ExtremeWare XOS 11.0.
Platform Availability
This command is available on all platforms with an Advanced Edge, a Core, or an Advanced Core
license.