IP Multicast Commands
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
1822
configure pim register-suppress-interval register-probe-
interval
configure pim register-suppress-interval <reg-interval> register-probe-
interval <probe_interval>
Description
Configures an interval for periodically sending null-registers.
Syntax Description
Default
The following defaults apply:
●
register-suppress-interval—60
●
register-probe-interval—5
Usage Guidelines
The register-probe-interval time should be set less than the register-suppress-interval time. By default, a
null register is sent every 55 seconds (
register-suppress-interval
-
register-probe-interval
).
A response to the null register is expected within register probe interval. By specifying a larger interval,
a CPU peak load can be avoided because the null-registers are generated less frequently. The register
probe time should be less than half of the register suppress time, for best results.
Example
The following command configures the register suppress interval and register probe time:
configure pim register-suppress-interval 90 register-probe time 10
History
This command was first available in ExtremeWare XOS 10.1.
Platform Availability
This command is available on all platforms.
reg-interval
Specifies an interval time in seconds. Range is 30 - 200 seconds. Default is
60.
probe-interval
Specifies an interval time in seconds. Default is 5.