Commands for Configuring Slots and Ports on a Switch
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
324
NOTE
On the BlackDiamond 10808 switch, 10 Gbps modules with a serial number lower than
804405-00-09
the software
redundant port feature cover only those failures where both the TX and RX paths fail. If a single strand of fiber is
pulled on these ports, the software redundant port cannot correctly recover from the failure.To display the serial
number of the module, issue the
show slot <slot_number>
command. (All the modules on the BlackDiamond
8800 series switch have this serial number or higher, as does the Summit X450 family of switches.)
Example
The following command configures a software-controlled redundant port:
configure ports 1:3 redundant 2:3
History
This command was available in ExtremeWare XOS 11.1.
Platform Availability
This command is available on all platforms.