Commands for Managing the Switch
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
208
Example
The following command displays the status of the installed power supply controllers:
show power controller
The following is sample output from this command:
PSUCTRL-1 information:
State: Operational
PartInfo: PSUCTRL-1 04334-00021 450117-00-01
Revision: 1.0
FailureCode: 0
Odometer: 337 days 7 hours since Nov-30-2004
Temperature: 32.14 deg C
Status: PSU CTRL Mode: Master
PSUCTRL-2 information:
State: Empty
If you have two power supply controllers installed, the switch displays output about both of the power
supply controllers:
PSUCTRL-1 information:
State: Operational
PartInfo: PSUCTRL-1 04334-00021 450117-00-01
Revision: 1.0
FailureCode: 0
Odometer: 17 days 5 hours 30 minutes since Oct-19-2004
Temperature: 35.1 deg C
Status: PSU CTRL Mode: Master
PSUCTRL-2 information:
State: Operational
PartInfo: PSUCTRL-2 04334-00068 450117-00-01
Revision: 1.0
FailureCode: 0
Odometer: 4 days 13 hours since Sep-21-2004
Temperature: 33.56 deg C
Status: PSU CTRL Mode: Backup
History
This command was first available in an ExtremeWare XOS 11.0.
Platform Availability
This command is available only on modular switches.