Commands for Configuring Slots and Ports on a Switch
ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
ExtremeWare XOS 11.5 Command Reference Guide
308
Guidelines for configuring mirroring on all switches .
This section summarizes the guidelines for
configuring switch port mirroring:
●
When you disable mirroring, all the filters are unconfigured.
●
You cannot mirror the monitor port.
●
The mirroring configuration is removed when you:
■
Delete a VLAN (for all VLAN-based filters).
■
Delete a port from a VLAN (for all VLAN-, port-based filters).
■
Unconfigure a slot (for all port-based filters on that slot).
●
Any mirrored port can also be enabled for load sharing (or link aggregation); however, each
individual port of the load-sharing group must be explicitly configured for mirroring.
●
The mirroring filters are not confined to a single module; they can have ports that span multiple
modules.
●
You cannot use the management port at all in switch port-mirroring configurations.
●
You cannot run ELSM and mirroring on the same port. If you attempt to enable mirroring on a port
that is already enabled for ELSM, the switch returns a message similar to the following:
Error: Port mirroring cannot enabled on an ELSM enabled port 1.
Summit X450 family of switches only.
The traffic filter can be defined based on one of the following
criteria:
●
Physical port—All data that traverses the port, regardless of VLAN configuration, is copied to the
monitor port. You can specify which traffic the port mirrors:
■
Ingress—Mirrors traffic received at the port.
■
Egress—Mirrors traffic sent from the port.
■
Ingress and egress—Mirrors all traffic forwarded by the port.
(If you omit the optional parameters, all traffic is forwarded; the default for port-based mirroring
is ingress and egress).
●
VLAN—All data to a particular VLAN, regardless of the physical port configuration, is copied to the
monitor port.
●
Virtual port—All data specific to a VLAN on a specific port is copied to the monitor port.
●
Only 8 VLANs can be mirrored on a given physical port.
●
Only traffic
ingressing
a VLAN can be monitored; you cannot specify ingressing or egressing traffic
when mirroring VLAN traffic.
●
When routing between VLANs, ingress mirrored traffic is presented to the monitor port as
modified
for routing.
●
When you specify the ingress traffic, the packet is mirrored after it is modified by the ingress process
and may include internal tagging and/or egress tagging.
●
Even if you select ingress and egress traffic, the packet is mirrored only the
first
time it matches a
mirror filter and is not mirrored on subsequent configured filters.
●
You cannot include the monitor port for a Summit X450 family of switches in a load-sharing group.