Monday
, November 26, 2001 1:09 pm
• In the Command Parameters on the Virtual Front Panel, select the:
Trigger source:
• Aux Contact if using an Auxiliary Contact channel on the
Event module
• Trigger In if the TDR9000 System module has the Triggers
option
Trigger event:
• Close
• Open
The trigger event is the change of state the TDR9000 is expecting
to see before recording the test data. During a First Trip Test, the
closing of the 52CS/T contacts initiates the recording. During a
First Close Test, the closing of the 52CS/C contacts initiates
recording.
• If using the “Aux Contact” trigger source, select the trigger
channel where the trigger signal is received. Select the pre-trigger
time, or leave it at the default, zero (see page 4-65).
• For each relay contact state measured, an Auxiliary Contact
channel must be activated, given a label and a phase. If the relay
contact state is measured using a Trigger In channel (the Triggers
option must be present on the System panel), there is no need to
activate an Auxiliary Contact channel for it. Activate only the
channels being used. When performing a First Close test, both the
52CS/T label in the Test Plan must be changed to 52CS/C and the
cables must be transferred, since this contact is being used to
trigger the Close operation.
• For each current or voltage waveform to be measured, an Analog
Channel must be activated, given a label and a phase. All Analog
currents are measured using Doble probes, except for the DC
supply voltage. Activate only the channels being used. When
performing a First Close test, the Trip Coil label must be changed
to Close Coil.
• If Motion transducers are permanently installed, the motion
channels must be activated, and a label and phase selected.
Содержание TDR9000
Страница 26: ...xxii 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 50: ...Step 5 Saving Test Results 1 24 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 98: ...3 28 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 200: ...Disconnecting After the Test 4 102 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 362: ...B 34 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 388: ...D 6 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 392: ...E 4 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 394: ...F 2 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 442: ...I 32 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 454: ...I 12 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...