Adapters and Transducers
I-14
72A-1898 Rev. A 11/01
Monday
, November 26, 2001 1:09 pm
Figure I.9 shows an adapter for use with HVB SF6 Gas circuit breakers
that uses an individual mechanism for each pole. A plate is removed
from each pole, the large metric bolt is threaded into the moving
element, and the spacer is attached to the point from which the plate was
removed using existing hardware. The travel rod is inserted through the
large holes in the spacer and is threaded into a tapped hole in the top of
the large metric bolt. The transducer is then centered on the travel rod
and clamped to the spacer.
Figure I.9 HVB SF6 Gas Circuit Breakers with
Independent Pole Operating Mechanisms (IPO)
Figure I.10 on page I-15 shows an adapter that mounts on the moving
contact assembly using existing hardware. The plate is clamped to the
top of the circuit breaker with the forked arms extending beyond the
bushing. The transducer is clamped to the support plate. The plate is bent
at the proper angle to ensure the travel rod does not touch the transducer
case during circuit breaker operation. Figure I.11 shows this adapter for
the 2000 Amp and above range.
Содержание TDR9000
Страница 26: ...xxii 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 50: ...Step 5 Saving Test Results 1 24 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 98: ...3 28 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 200: ...Disconnecting After the Test 4 102 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 362: ...B 34 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 388: ...D 6 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 392: ...E 4 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 394: ...F 2 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 442: ...I 32 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...
Страница 454: ...I 12 72A 1898 Rev A 11 01 Monday November 26 2001 1 09 pm...