Parameter list
Parameters
1-79
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
The saturation characteristics (flux as a function of the magnetizing current) is defined using 4 points.
This parameter specifies the x coordinate (magnetizing current) for the 1st value pair of the characteristic.
Sets the first magnetizing current of the saturation characteristic as a [%] referred to the rated magnetizing current
(p0331).
Dependency:
The following applies for the magnetizing currents:
p0366 < p0367 < p0368 < p0369
Refer to: p0362
Description:
The saturation characteristics (flux as a function of the magnetizing current) is defined using 4 points.
This parameter specifies the x coordinate (magnetizing current) for the 2nd value pair of the characteristic.
Sets the second magnetizing current of the saturation characteristic as a [%] referred to the rated magnetizing cur-
rent (p0331).
Dependency:
The following applies for the magnetizing currents:
p0366 < p0367 < p0368 < p0369
Refer to: p0363
Description:
The saturation characteristics (flux as a function of the magnetizing current) is defined using 4 points.
This parameter specifies the x coordinate (magnetizing current) for the 3rd value pair of the characteristic.
Sets the third magnetizing current of the saturation characteristic as a [%] referred to the rated magnetizing current
(p0331).
Dependency:
The following applies for the magnetizing currents:
p0366 < p0367 < p0368 < p0369
Refer to: p0364
p0366[0...n]
Saturation characteristic I_mag 1 / Mot sat. I_mag 1
VECTOR
Can be changed:
C2, U, T
Access level:
4
Data type:
Floating Point
Data set:
MDS
Function diagram:
-
P-Group:
Motor
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
25.0 [%]
500.0 [%]
50.0 [%]
p0367[0...n]
Saturation characteristic I_mag 2 / Mot sat. I_mag 2
VECTOR
Can be changed:
C2, U, T
Access level:
4
Data type:
Floating Point
Data set:
MDS
Function diagram:
-
P-Group:
Motor
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
25.0 [%]
500.0 [%]
75.0 [%]
p0368[0...n]
Saturation characteristic I_mag 3 / Mot sat. I_mag 3
VECTOR
Can be changed:
C2, U, T
Access level:
4
Data type:
Floating Point
Data set:
MDS
Function diagram:
-
P-Group:
Motor
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
25.0 [%]
500.0 [%]
150.0 [%]