Parameters
Parameter list
1-196
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Note:
This parameter can be freely interconnected.
The value has the above significance if it is interconnected from connector input p1528.
Description:
Displays the upper torque/force limit of all torque/force limits without offset.
Dependency:
p1400 bit 4 = 0: top / bottom
p1400 bit 4 = 1: motoring / regenerating
Refer to: p1520, p1521, p1522, p1523
Description:
Displays the lower torque/force limit of all torque/force limits without offset.
Dependency:
p1400 bit 4 = 0: top / bottom
p1400 bit 4 = 1: motoring / regenerating
Refer to: p1520, p1521, p1522, p1523
Description:
Sets the signal source for the scaling of the upper torque limit in p1522.
Description:
Sets the signal source for the scaling of the lower torque limit in p1523.
Description:
Sets the power limit when motoring.
r1526
Torque limit, upper/motoring without offset / M_max up. w/o offs
VECTOR (n/M)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
5620,
5630, 6630, 6640
P-Group:
Control
Units group:
TORQUE
Unit selection:
-
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
r1527
Torque limit, lower/regenerative without offset / M_max low w/o offs
VECTOR (n/M)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
5620,
5630, 6630, 6640
P-Group:
Control
Units group:
TORQUE
Unit selection:
-
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
p1528[0...n]
CI: Torque limit upper scaling / M_max upper scal
VECTOR (n/M)
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Data set:
CDS
Function diagram:
6630
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
1524[0]
p1529[0...n]
CI: Torque limit lower scaling / M_max lower scal
VECTOR (n/M)
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Data set:
CDS
Function diagram:
6630
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
1525[0]
p1530[0...n]
Power limit, motoring / P_max mot
VECTOR (n/M)
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
5640,
6640
P-Group:
Control
Units group:
POWER_P3
Unit selection:
-
Min Max
Factory
setting
0.00 [kW]
10000.00 [kW]
0.00 [kW]