![Siemens SINAMICS G List Manual Download Page 339](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180339.webp)
Parameter list
Parameters
1-339
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Connector output for interconnecting the PZD (setpoints) received from the COMM BOARD in the word format.
p8840
COMM BOARD monitoring time / CB t_monitoring
CU (CB)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Communication
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
0 [ms]
65535000 [ms]
20 [ms]
p8841[0...39]
COMM BOARD send configuration data / CB S_config_data
CU (CB)
Can be changed:
U, T
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Communication
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 65535
0
p8842
COMM BOARD start configuration / CB config start
CU (CB)
Can be changed:
U, T
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Communication
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 1
0
r8849[0...139]
COMM BOARD receive configuration data / CB E_config_data
CU (CB)
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Communication
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r8850[0...15]
CO: COMM BOARD PZD receive word / CB PZD recv word
VECTOR
Can be changed:
-
Access level:
3
Data type:
Integer16
Data set:
-
Function diagram:
9204,
9206
P-Group:
Communication
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-