Parameter list
Parameters
1-113
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Values:
0:
Limiting off
1:
Limiting on
Index:
[0] = T0
[1] = T1
[2] = T2
Note:
Limiting on:
If signals are output outside the permissible measuring range, the signal is limited to 4.98 V or to V.
Limiting off:
If signals are output outside the permissible measuring range, this causes signal overflow. In the case of signal
overflow, the signal jumps from 0 V to 4.98 V or from 4.98 V to 0 V.
Description:
Displays the normalization of the signal to be output. A change in the output voltage by 1 volt corresponds to the
value in this parameter. The units are determined by the interconnected test signal.
Index:
[0] = T0
[1] = T1
[2] = T2
Dependency:
Refer to: p0771, r0772, r0774, p0777, p0778, p0779, p0780, p0783, p0784
Note:
Example:
r0786[0] = 1500.0 and the measuring signal is r0063 (CO: Smoothed speed actual value [RPM]).
A change of 1 V at the output of test socket T0 corresponds to 1500.0 [RPM].
Description:
Sets the physical address to output signals via the test sockets.
Index:
[0] = T0
[1] = T1
[2] = T2
Dependency:
Changes only become effective if p0776 does not equal 99.
Refer to: p0789, r0790
Description:
Sets the gain of a signal output of a physical address via test sockets.
Index:
[0] = T0
[1] = T1
[2] = T2
Dependency:
Changes only become effective if p0776 does not equal 99.
Refer to: p0788
r0786[0...2]
Test socket normalization per volt / TestSktNorm/Volt
CU
Can be changed:
-
Access level:
2
Data type:
Floating Point
Data set:
-
Function diagram:
8134
P-Group:
Terminals
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
p0788[0...2]
Test sockets physical address / Test skt PhyAddr
CU
Can be changed:
U, T
Access level:
4
Data type:
Unsigned32
Data set:
-
Function diagram:
-
P-Group:
Terminals
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p0789[0...2]
Test sockets physical address gain / TestSktPhyAddrGain
CU
Can be changed:
U, T
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Terminals
Units group:
-
Unit selection:
-
Min Max
Factory
setting
-340.2823466E36 340.2823466E36
1.00000