![Siemens SINAMICS G List Manual Download Page 236](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180236.webp)
Parameters
Parameter list
1-236
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
Description:
Selects the PZD (actual values) with word format to be sent to the PROFIBUS master.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
[15] = PZD 16
Dependency:
Refer to: p2061
Description:
Displays the PZD (actual values) with word format sent to the PROFIBUS master.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
p2051[0...15]
CI: PROFIBUS PZD send word / PB PZD send word
VECTOR
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
2470
P-Group:
Communication
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
r2053[0...4]
PROFIBUS diagnostics send PZD word / PB diag send word
CU, TB30, TM31
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Communication
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
Bit 0
Off
On
-
01
Bit 1
Off
On
-
02
Bit 2
Off
On
-
03
Bit 3
Off
On
-
04
Bit 4
Off
On
-
05
Bit 5
Off
On
-