Parameters
Parameter list
1-318
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the maximum absolute deviation of the measured DC link voltage from the average value.
The deviation of the individual voltages from the average value is displayed in r7030.
Dependency:
Refer to: r7030
Refer to: A05053
Description:
Using this correction time, the valve lockout time in phase U (p1828) is compensated for a positive phase current
for the particular motor module. This therefore takes into account a spread in the valve lockout times of motor mod-
ules in a parallel circuit configuration.
Dependency:
Refer to: p1828
Description:
Using this correction time, the valve lockout time in phase U (p1828) is compensated for a negative phase current
for the particular motor module. This therefore takes into account a spread in the valve lockout times of motor mod-
ules in a parallel circuit configuration.
Dependency:
Refer to: p1828
Description:
Using this correction time, the valve lockout time in phase V (p1829) is compensated for a positive phase current for
the particular motor module. This therefore takes into account a spread in the valve lockout times of motor modules
in a parallel circuit configuration.
Dependency:
Refer to: p1829
r7031
Parallel circuit configuration, maximum deviation DC link voltage / Vdc max deviation
VECTOR (Parallel)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Displays, signals
Units group:
VOLTAGE_DC
Unit selection:
-
Min Max
Factory
setting
- [V]
- [V]
- [V]
p7040[0...n]
Parallel circuit configuration, valve lockout time correction, phase U positive / Comp
t_interl Upos
VECTOR (Parallel)
Can be changed:
U, T
Access level:
4
Data type:
Floating Point
Data set:
PDS
Function diagram:
-
P-Group:
Modulation
Units group:
TIME_M6
Unit selection:
-
Min Max
Factory
setting
0.00 [µs]
1000000.00 [µs]
0.00 [µs]
p7041[0...n]
Parallel circuit configuration, valve lockout time correction, phase U negative / Comp
t_interl Uneg
VECTOR (Parallel)
Can be changed:
U, T
Access level:
4
Data type:
Floating Point
Data set:
PDS
Function diagram:
-
P-Group:
Modulation
Units group:
TIME_M6
Unit selection:
-
Min Max
Factory
setting
0.00 [µs]
1000000.00 [µs]
0.00 [µs]
p7042[0...n]
Parallel circuit configuration, valve lockout time correction, phase V positive / Comp
t_interl Vpos
VECTOR (Parallel)
Can be changed:
U, T
Access level:
4
Data type:
Floating Point
Data set:
PDS
Function diagram:
-
P-Group:
Modulation
Units group:
TIME_M6
Unit selection:
-
Min Max
Factory
setting
0.00 [µs]
1000000.00 [µs]
0.00 [µs]