![Siemens SINAMICS G List Manual Download Page 325](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180325.webp)
Parameter list
Parameters
1-325
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the maximum output current of the power module.
The minimum value of all power modules multiplied by the number motor modules is displayed in r0067.
Description:
Displays actual absolute current.
The summed value of all power modules is displayed in r0068.
Description:
Displays the measured actual value of phase U as peak value.
The summed value of all power modules is displayed in r0069[0].
Description:
Displays the measured actual value of phase V as peak value.
The summed value of all power modules is displayed in r0069[1].
Description:
Displays the measured actual value of phase W as peak value.
The summed value of all power modules is displayed in r0069[2].
r7220[0...n]
Parallel circuit configuration, maximum drive output current / Drv I_output max
VECTOR (Parallel)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
PDS
Function diagram:
-
P-Group:
Displays, signals
Units group:
CURRENT_AC_EFF
Unit selection:
-
Min Max
Factory
setting
- [Aeff]
- [Aeff]
- [Aeff]
r7222[0...n]
Parallel circuit configuration, absolute current actual value / I_act abs.val.
VECTOR (Parallel)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
PDS
Function diagram:
-
P-Group:
Displays, signals
Units group:
CURRENT_AC_EFF
Unit selection:
-
Min Max
Factory
setting
- [Aeff]
- [Aeff]
- [Aeff]
r7223[0...n]
Parallel circuit configuration, phase current actual value phase U / I_phase U act val
VECTOR (Parallel)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
PDS
Function diagram:
-
P-Group:
Displays, signals
Units group:
CURRENT_AC_PP
Unit selection:
-
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7224[0...n]
Parallel circuit configuration, phase current actual value phase V / I_phase V act val
VECTOR (Parallel)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
PDS
Function diagram:
-
P-Group:
Displays, signals
Units group:
CURRENT_AC_PP
Unit selection:
-
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7225[0...n]
Parallel circuit configuration, phase current actual value phase W / I_phase W act val
VECTOR (Parallel)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
PDS
Function diagram:
-
P-Group:
Displays, signals
Units group:
CURRENT_AC_PP
Unit selection:
-
Min Max
Factory
setting
- [A]
- [A]
- [A]