Parameters
Parameter list
1-218
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the filter time constant of the DC link voltage used to calculate the modulation depth.
Description:
DC link voltage that is used to convert the setpoint voltage into an equivalent modulation depth.
Note:
P1737 can be used for filtering.
Description:
DC link voltage used to determine the maximum possible output voltage.
Description:
Displays the effective modulator mode.
Values:
1:
Flat top modulation (FLB)
2:
Space vector modulation (SVM)
3:
Edge modulation from 28 Hz; 23:3
4:
Edge modulation from 28 Hz; 19:1
5:
Edge modulation from 60 Hz; 17:3
6:
Edge modulation from 60 Hz; 17:1
7:
Edge modulation from 100 Hz; 9:2
8:
Edge modulation from 100 Hz; 9:1
Description:
Sets the minimum ratio between the pulse frequency and the output frequency.
Notice:
If the ratio between the pulse frequency and the output frequency is reduced, then oscillations can occur in the out-
put current that can result in significant levels of current ripple with the appropriate negative effects.
p1806[0...n]
Filter time constant Vdc correction / T_filt Vdc_corr
VECTOR
Can be changed:
U, T
Access level:
4
Data type:
Floating Point
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
0.0 [ms]
10000.0 [ms]
0.0 [ms]
r1807
Actual DC-link voltage to calculate the modulation depth / VdcActValMod_depth
VECTOR
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Displays, signals
Units group:
VOLTAGE_DC
Unit selection:
-
Min Max
Factory
setting
- [V]
- [V]
- [V]
r1808
DC link voltage actual value for V_max calculation / Vdc act val U_max
VECTOR
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Displays, signals
Units group:
VOLTAGE_DC
Unit selection:
-
Min Max
Factory
setting
- [V]
- [V]
- [V]
r1809
Modulator mode actual / Modulator mode act
VECTOR
Can be changed:
-
Access level:
4
Data type:
Integer16
Data set:
-
Function diagram:
-
P-Group:
Modulation
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
p1817
Minimum ratio, pulse frequency to the output frequency / Min f_puls / f_max
VECTOR
Can be changed:
C2
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Drive converter
Units group:
-
Unit selection:
-
Min Max
Factory
setting
8.3 15.0
12.5