Parameters
Parameter list
1-56
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Note:
A value of 99 means that no encoder has been assigned to this drive data set (not configured).
The same value must be entered for all of the indices.
Description:
Displays the properties supported by the power module.
Description:
Displays the version of loader 1 (first level loader).
Dependency:
Refer to: r0018, r0128, r0148, r0158, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description:
Displays the version of loader 2 (second level loader).
Dependency:
Refer to: r0018, r0128, r0148, r0158, r0197
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description:
Freely assignable name for a drive object.
In the commissioning software, this name cannot be entered using the expert list, but is specified in the configura-
tion assistant. The object name can be subsequently modified in the Project Navigator using standard Windows
resources.
r0192
Power module properties / PM properties
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
-
P-Group:
Drive converter
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
Edge modulation possible
No
Yes
-
01
Free telegram can be selected
No
Yes
-
02
Smart mode possible for active line module No
Yes
-
03
Safety Integrated possible for VECTOR
No
Yes
-
07
SERVO: Pulse frequency changeover DDS-
dependent
No
Yes
-
r0197
Loader 1 version / Loader 1 version
CU
Can be changed:
-
Access level:
1
Data type:
Unsigned32
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r0198
Loader 2 version / Loader 2 version
CU
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
p0199[0...23]
Drive object name / DO name
All objects
Can be changed:
U, T
Access level:
2
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 255
0