Parameter list
Parameters
1-211
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the hysteresis for the changeover speed/velocity of the motor model.
Dependency:
Refer to: p1752, p1755
Note:
The value is entered relative to p1404, p1752 or p1755.
Description:
Sets the minimum time for falling below the changeover speed/velocity when changing from closed-loop controlled
operation to open-loop controlled operation.
Dependency:
Refer to: p1755, p1756
Description:
Sets the minimum time for exceeding the changeover speed/velocity when changing from open-loop controlled
operation to closed-loop controlled operation.
Dependency:
Refer to: p1755, p1756
Description:
Sets the proportional gain of the controller for speed adaptation with encoder
Description:
Sets the integral-action time of the controller for speed adaptation with encoder
p1756
Motor model changeover speed hysteresis / MotMod n_chgov.Hys
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
0.0 [%]
90.0 [%]
5.0 [%]
p1758[0...n]
Motor model changeover delay time, closed/open-loop control / MotMod t cl_op
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
100 [ms]
2000 [ms]
1000 [ms]
p1759[0...n]
Motor model changeover delay time open/closed loop control / MotMod t op_cl
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
0 [ms]
2000 [ms]
0 [ms]
p1760[0...n]
Motor model with encoder speed adaptation Kp / MotMod wE n_ada Kp
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
-
Unit selection:
p0528
Min Max
Factory
setting
0.000 100000.000
1000.000
p1761[0...n]
Motor model with encoder speed adaptation Tn / MotMod wE n_ada Tn
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
0 [ms]
1000 [ms]
4 [ms]