Dependency:
The setpoint for the input signals is specified using p4096.
Refer to: p4096
Note:
DI: Digital input
DI/DO: Bidirectional digital input/output
This parameter is not saved when data is backed-up (p0971, p0977).
Description:
Sets the setpoint for the input signals in the simulation mode of the digital inputs of the terminal board 30 (TB30).
Dependency:
The simulation of a digital input is selected using p4095.
Refer to: p4095
Note:
DI: Digital input
This parameter is not saved when data is backed-up (p0971, p0977).
Description:
Sets the setpoint for the input signals in the simulation mode of the digital inputs of terminal module 31 (TM31).
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
DI 0 (X520.1)
Terminal eval.
Simulation
-
01
DI 1 (X520.2)
Terminal eval.
Simulation
-
02
DI 2 (X520.3)
Terminal eval.
Simulation
-
03
DI 3 (X520.4)
Terminal eval.
Simulation
-
04
DI 4 (X530.1)
Terminal eval.
Simulation
-
05
DI 5 (X530.2)
Terminal eval.
Simulation
-
06
DI 6 (X530.3)
Terminal eval.
Simulation
-
07
DI 7 (X530.4)
Terminal eval.
Simulation
-
08
DI/DO 8 (X541.2)
Terminal eval.
Simulation
-
09
DI/DO 9 (X541.3)
Terminal eval.
Simulation
-
10
DI/DO 10 (X541.4)
Terminal eval.
Simulation
-
11
DI/DO 11 (X541.5)
Terminal eval.
Simulation
-
p4096
TB30 digital inputs, simulation mode setpoint / TB30 DI sim setpt
TB30
Can be changed:
U, T
Access level:
2
Data type:
Unsigned32
Data set:
-
Function diagram:
1790,
9100
P-Group:
Commands
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0000 bin
1111 bin
0000 bin
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
DI 0 (X481.1)
Low
High
-
01
DI 1 (X481.2)
Low
High
-
02
DI 2 (X481.3)
Low
High
-
03
DI 3 (X481.4)
Low
High
-
p4096
TM31 digital inputs, simulation mode setpoint / TM31 DI sim setpt
TM31
Can be changed:
U, T
Access level:
2
Data type:
Unsigned32
Data set:
-
Function diagram:
1840,
9550, 9552, 9560, 9562
P-Group:
Terminals
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0000 bin
0000 1111 1111 1111 bin
0000 bin
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
DI 0 (X520.1)
Low
High
-
01
DI 1 (X520.2)
Low
High
-