Overview of parameters
Parameters
1-13
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
pxxxx[0...n]
Parameter number
The parameter number consists of a "p" or "r", followed by the parameter number
and the index (optional).
Examples of number representation in the parameter list:
Other examples of notation in the documentation:
The following applies to adjustable parameters:
The "shipped" parameter value is specified under "Factory setting" with the rele-
vant unit in square parenthesis. The value can be adjusted within the range
defined by "Min" and "Max".
The term "linked parameterization" is used in cases where changes to adjustable
parameters affect the settings of other parameters.
Linked parameterization can occur, for example, as a result of the following
actions or parameters:
•
Execute macros
p0015, p0700, p1000, p1500
•
Set PROFIBUS telegram (BICO interconnection)
p0922
•
Set component lists
p0230, p0300, p0301, p0400
•
Calculate and preset automatically
p0112, p0340, p0578, p3900
•
Restore factory settings
p0970
The following applies to visualization parameters:
The fields "Min", "Max" and "Factory setting" are specified with a dash "-" and the
relevant unit in square parenthesis.
•
p...
Adjustable parameter (read and write parameter)
•
r...
Visualization parameters (read-only)
•
p0918
Adjustable parameter 918
•
p0099[0...3]
Adjustable parameter 99, indices 0 to 3
•
p1001[0...n]
Adjustable parameter 1001, indices 0 to n (n = configurable)
•
r0944
Visualization parameter 944
•
p1070[1]
Adjustable parameter 1070, index 1
•
p2098[1].3
Adjustable parameter 2098, index 1 bit 3
•
r0945[2](3)
Visualization parameter 945, index 2 of drive object 3
•
p0795.4
Adjustable parameter 795, bit 4