Parameters
Parameter list
1-270
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Note:
Re bit 01, 02:
The speed threshold value 2 is set in p2155.
Description:
Displays the second status word for monitoring functions.
Note:
Re bit 10:
The torque threshold value 1 is set in p2174.
Re bit 07:
For servo drives, bit 07 is not used and is always inactive.
Description:
Displays the third status word for monitoring functions.
Note:
Re bit 00:
The speed threshold value 3 is set in p2161.
Re bit 01:
The comparison value is set in p2141.
Re bit 11:
The torque threshold value 2 is set in p2194.
Bit field:
Bit
Signal name
0 signal
1 signal
FP
01
|n_act| <= speed threshold value 2
No
Yes
8010
02
|n_act| > speed threshold value 2
No
Yes
8010
03
n_act >= 0
No
Yes
8010
06
n_act > n_max
No
Yes
8010
07
Speed setp - act val deviation in tolerance
t_off
No
Yes
8010
r2198
CO/BO: Status word monitoring 2 / ZSW monitor 2
VECTOR
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Data set:
-
Function diagram:
1530,
2536
P-Group:
Messages
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
0 signal
1 signal
FP
04
|n_set| < p2161
No
Yes
8010
05
n_set > 0
No
Yes
8010
06
Motor locked
No
Yes
8012
07
Motor stalled
No
Yes
8012
10
Torque setpoint < torque threshold value 1
No
Yes
8012
11
Load monitoring signals an alarm
No
Yes
8013
12
Load monitoring signals a fault condition
No
Yes
8013
r2199
CO/BO: Status word monitoring 3 / ZSW monitor 3
VECTOR
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Data set:
-
Function diagram:
1530,
2536
P-Group:
Messages
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
|n_act| < speed threshold value 3
No
Yes
8010
01
f or n comparison value reached or
exceeded
No
Yes
8010
04
Speed setp - act val deviation in tolerance
t_on
No
Yes
8010
05
Ramp-up/ramp-down completed
No
Yes
8010
11
Torque utilization < torque threshold value 2 No
Yes
8012