Parameters
Parameter list
1-30
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the smoothed absolute actual current value.
Dependency:
Refer to: r0068
Note:
A_INF, VECTOR: Smoothing time constant = 300 ms
SERVO: Smoothing time constant = 100 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The absolute current actual value is available smoothed (r0027) and unsmoothed (r0068).
Description:
Displays the smoothed actual value of the modulation depth.
Dependency:
Refer to: r0074
Note:
A_INF: Smoothing time constant = 300 ms
SERVO, VECTOR: Smoothing time constant = 100 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The modulation depth is available smoothed (r0028) and unsmoothed (r0074).
Description:
Displays the smoothed field-generating actual current.
Dependency:
Refer to: r0076
Note:
SERVO: Smoothing time constant = 100 ms
VECTOR: Smoothing time constant = 300 ms
The signal is not suitable as process quantity and may only be used as display quantity.
The field-generating current actual value is available smoothed (r0029) and unsmoothed (r0076).
Description:
Displays the smoothed torque-generating actual current.
Dependency:
Refer to: r0078
r0027
Absolute actual current, smoothed / I_act abs.val.smth
VECTOR
Can be changed:
-
Access level:
2
Data type:
Floating Point
Data set:
-
Function diagram:
5730,
6714, 8950
P-Group:
Displays, signals
Units group:
CURRENT_AC_EFF
Unit selection:
-
Min Max
Factory
setting
- [Aeff]
- [Aeff]
- [Aeff]
r0028
Modulation depth, smoothed / Modulat depth smth
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
5730,
8940, 8950
P-Group:
Displays, signals
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
r0029
Drive, smoothed field-generating current actual value / Drv Id_act smooth
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
5730
P-Group:
Displays, signals
Units group:
CURRENT_AC_EFF
Unit selection:
-
Min Max
Factory
setting
- [Aeff]
- [Aeff]
- [Aeff]
r0030
Current actual value, torque-generating, smoothed / Iq_act smooth
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
5730
P-Group:
Displays, signals
Units group:
CURRENT_AC_EFF
Unit selection:
-
Min Max
Factory
setting
- [Aeff]
- [Aeff]
- [Aeff]