Description:
Displays the vibration frequencies determined by the vibration test.
Index:
[0] = Frequency low
[1] = Frequency high
Dependency:
Refer to: p1959
Refer to: A07985
Description:
Displays the standard deviations of the vibration frequencies determined by the vibration test
Index:
[0] = Standard deviation of low frequency
[1] = Standard deviation of high frequency
Dependency:
Refer to: p1959
Refer to: A07985
Description:
Displays the number of periods determined by the vibration test.
Index:
[0] = No. of periods of the low frequency
[1] = No. of periods of the high frequency
Dependency:
Refer to: p1959
Refer to: A07985
Description:
Displays the number of pulses determined during the vibration test.
Note:
A negative signal indicates an incorrect polarity of the encoder signal.
r1970[0...1]
Speed controller optimization vibration test vibration frequency determined / n_opt
f_vibration
VECTOR (n/M)
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Motor identification
Units group:
FREQUENCY
Unit selection:
-
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
r1971[0...1]
Speed controller optimization vibration test standard deviation determined / n_opt
std. deviat.
VECTOR (n/M)
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Motor identification
Units group:
FREQUENCY
Unit selection:
-
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
r1972[0...1]
Speed controller optimization vibration test cycle number determined / n_opt period
No.
VECTOR (n/M)
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r1973
Speed controller optimization encoder test pulse number determined / n_opt pulse
No.
VECTOR (n/M)
Can be changed:
-
Access level:
3
Data type:
Integer32
Data set:
-
Function diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-