Parameters
Parameter list
1-206
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Activates data transfer for parameter changes for the filter.
p1699 = 0:
The new filter data are immediately transferred.
p1699 = 1:
The new filter data are only transferred when this parameter is reset.
Dependency:
Refer to: p1416, p1657, p1658, p1659, p1660, p1661, p1662, p1663, p1664, p1665, p1666
Description:
Sets the scaling of the dynamic current controller pre-control for the torque/force-generating current component Isq.
Description:
Sets the proportional gain of the current controller for the lower adaptation current range. This value is automatically
preset using p3900 or p0340 when commissioning has been completed.
Dependency:
p0391, p0392 and p0393 are only available for SERVO.
Note:
For p0393 = 100 %, the current controller adaptation is disabled and p1715 is effective over the entire range.
Description:
Sets the integral-action time of the current controller.
Dependency:
Refer to: p1715
p1699
Filter data transfer / Filt data transfer
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Integer16
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 1
0
p1703[0...n]
Isq current controller pre-control scaling / Isq_ctr_prectrScal
VECTOR (n/M)
Can be changed:
U, T
Access level:
4
Data type:
Floating Point
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
0.0 [%]
200.0 [%]
70.0 [%]
p1715[0...n]
Current controller P gain / I_ctrl Kp
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
5714,
6714
P-Group:
Control
Units group:
GAIN_CURRENT_CTRL
Unit selection:
p0528
Min Max
Factory
setting
0.000 [V/A]
100000.000 [V/A]
0.000 [V/A]
p1717[0...n]
Current controller integral-action time / I_ctrl Tn
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
5714,
6714
P-Group:
Control
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
0.00 [ms]
1000.00 [ms]
2.00 [ms]