Parameter list
Parameters
1-347
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the number of signal sources from this drive to other drives/drive objects (binector output/connector out-
put, BO/CO).
Dependency:
Refer to: r9491, r9492, p9493
Description:
Displays the signal receiver list (binector input/connector input, BI/CI) for the first interconnections between this
drive and other drives/drive objects.
Dependency:
Refer to: r9490, r9492, p9493
Notice:
A drive cannot be deleted if this list is not empty! Otherwise, another drive would continue to attempt to read a sig-
nal from a drive that no longer existed.
Note:
All indices of r9491 to p9493 designate the same interconnection. r9491[x] contains the signal receiver and r9492[x]
the matching signal source; p9493[x] can be set to modify the interconnection.
Description:
Displays the signal source list (binector output/connector output, BO/CO) for the first interconnections between this
drive and other drives/drive objects.
Dependency:
Refer to: r9490, r9491, p9493
Notice:
A drive cannot be deleted if this list is not empty! Otherwise, another drive would continue to attempt to read a sig-
nal from a drive that no longer existed.
Note:
All indices of r9491 to p9493 designate the same interconnection. r9491[x] contains the signal receiver and r9492[x]
the matching signal source; p9493[x] can be set to modify the interconnection.
Description:
Resets the BICO interconnections to other drives to 0, 1 or to the factory setting. Each interconnection can be indi-
vidually reset.
Values:
0:
Set connection to 0
1:
Set connection to 1 (100 %)
2:
Set connection to factory setting
15:
Finished
Dependency:
Refer to: r9490, r9491, r9492
r9490
Number of BICO interconnections to other drives / No. BICO to drive
TB30, TM31,
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r9491[0...9]
BI/CI of BICO interconnections to other drives / BI/CI to drive
TB30, TM31,
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r9492[0...9]
BO/CO of BICO interconnections to other drives / BO/CO to drive
TB30, TM31,
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
p9493[0...9]
Reset BICO interconnections to other drives / Reset BICO to drv
TB30, TM31,
VECTOR
Can be changed:
T
Access level:
3
Data type:
Integer16
Data set:
-
Function diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 15
15