Parameter list
Parameters
1-269
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the speed/torque envelop curve for the load monitoring.
Dependency:
The following applies: p2189 > p2190
Refer to: p2184, p2190
Refer to: A07926
Description:
Sets the speed/torque envelop curve for the load monitoring.
Dependency:
The following applies: p2190 < p2189
Refer to: p2184, p2189
Refer to: A07926
Description:
Sets the delay time to evaluate the load monitoring.
Description:
Sets the torque/force threshold value for the signal "Torque utilization < torque threshold value 2" (BO: r2199.11).
Dependency:
Refer to: r0033, r2199
Description:
Displays the first status word for monitoring functions.
p2189[0...n]
Load monitoring torque threshold 3, upper / M_thresh 3 upper
VECTOR (Extended
msg)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
8013
P-Group:
Messages
Units group:
TORQUE
Unit selection:
-
Min Max
Factory
setting
0.00 [Nm]
99999.00 [Nm]
99999.00 [Nm]
p2190[0...n]
Load monitoring torque threshold 3, lower / M_thresh 3 lower
VECTOR (Extended
msg)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
8013
P-Group:
Messages
Units group:
TORQUE
Unit selection:
-
Min Max
Factory
setting
0.00 [Nm]
99999.00 [Nm]
0.00 [Nm]
p2192[0...n]
Load monitoring, delay time / Load monit t_del
VECTOR (Extended
msg)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
8013
P-Group:
Messages
Units group:
TIME
Unit selection:
-
Min Max
Factory
setting
0.00 [s]
65.00 [s]
10.00 [s]
p2194[0...n]
Torque threshold value 2 / M_thresh val 2
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
8012
P-Group:
Messages
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
0.00 [%]
100.00 [%]
90.00 [%]
r2197
CO/BO: Status word monitoring 1 / ZSW monitor 1
VECTOR
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Data set:
-
Function diagram:
1530,
2534
P-Group:
Messages
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-