![Siemens SINAMICS G List Manual Download Page 316](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180316.webp)
Parameters
Parameter list
1-316
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Dependency:
Refer to: r7251
Refer to: A05052
Description:
Sets the alarm threshold to detect dissymmetry of the DC link voltages in the parallel circuit configuration.
The deviation between the measured values and average value is evaluated. The specified value is referred to the
rated link voltage.
Dependency:
Refer to: A05053
Description:
Displays the deviation between the measured current actual value of phase U and the average value as peak value.
The maximum deviation from the average value is displayed in r7025.
Dependency:
Refer to: r7021, r7022, r7025
Description:
Displays the deviation between the measured current actual value of phase V and the average value as peak value.
The maximum deviation from the average value is displayed in r7026.
Dependency:
Refer to: r7020, r7022, r7026
Description:
Displays the deviation between the measured current actual value of phase W and the average value as peak
value.
The maximum deviation from the average value is displayed in r7027.
Dependency:
Refer to: r7020, r7021, r7027
p7011
Parallel circuit configuration, DC link voltage dissymmetry, alarm threshold /
Vdc_dissym A thrsh
VECTOR (Parallel)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Modulation
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
2 [%]
100 [%]
10 [%]
r7020[0...n]
Parallel circuit configuration, deviation current in phase U / Phase U curr dev
VECTOR (Parallel)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
PDS
Function diagram:
-
P-Group:
Displays, signals
Units group:
CURRENT_AC_PP
Unit selection:
-
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7021[0...n]
Parallel circuit configuration, deviation current in phase V / Phase V curr dev
VECTOR (Parallel)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
PDS
Function diagram:
-
P-Group:
Displays, signals
Units group:
CURRENT_AC_PP
Unit selection:
-
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7022[0...n]
Parallel circuit configuration, deviation current in phase W / Phase W curr dev
VECTOR (Parallel)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
PDS
Function diagram:
-
P-Group:
Displays, signals
Units group:
CURRENT_AC_PP
Unit selection:
-
Min Max
Factory
setting
- [A]
- [A]
- [A]